2025-09-30T20:16:45.446Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2025-09-30T20:16:45.552Z|00002|ovs_numa|INFO|Discovered 6 CPU cores on NUMA node 0 2025-09-30T20:16:45.552Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 6 CPU cores 2025-09-30T20:16:45.553Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2025-09-30T20:16:45.553Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2025-09-30T20:16:45.555Z|00006|dpdk|INFO|DPDK Disabled - Use other_config:dpdk-init to enable 2025-09-30T20:16:45.564Z|00007|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.5-115.el9s 2025-09-30T20:24:14.359Z|00008|memory|INFO|255460 kB peak resident set size after 447.6 seconds 2025-09-30T20:24:14.360Z|00009|memory|INFO|idl-cells-Open_vSwitch:17 2025-09-30T20:24:14.361Z|00010|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2025-09-30T20:24:14.361Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2025-09-30T20:24:14.362Z|00012|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2025-09-30T20:24:14.362Z|00013|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2025-09-30T20:24:14.362Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2025-09-30T20:24:14.362Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2025-09-30T20:24:14.362Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2025-09-30T20:24:14.362Z|00017|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2025-09-30T20:24:14.362Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2025-09-30T20:24:14.362Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2025-09-30T20:24:14.362Z|00020|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2025-09-30T20:24:14.362Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2025-09-30T20:24:14.362Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2025-09-30T20:24:14.362Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2025-09-30T20:24:14.362Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2025-09-30T20:24:14.362Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2025-09-30T20:24:14.362Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2025-09-30T20:24:14.362Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2025-09-30T20:24:14.362Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2025-09-30T20:24:14.362Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2025-09-30T20:24:14.362Z|00030|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2025-09-30T20:24:14.363Z|00031|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2025-09-30T20:24:14.363Z|00032|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2025-09-30T20:24:14.363Z|00033|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 6, setting n-revalidator-threads to 2 2025-09-30T20:24:14.363Z|00034|ofproto_dpif_upcall|INFO|Starting 8 threads 2025-09-30T20:24:14.451Z|00035|netdev|WARN|failed to set MTU for network device br-ex: No such device 2025-09-30T20:24:14.452Z|00036|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2025-09-30T20:24:14.452Z|00037|bridge|INFO|bridge br-ex: using datapath ID 00005254002bccb1 2025-09-30T20:24:14.452Z|00038|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2025-09-30T20:24:14.457Z|00039|bridge|INFO|bridge br-ex: added interface enp1s0 on port 1 2025-09-30T20:24:14.458Z|00001|ofproto_dpif_upcall(handler5)|INFO|received packet on unassociated datapath port 2 (no OpenFlow port for datapath port 2) 2025-09-30T20:24:14.466Z|00040|netdev|WARN|failed to set MTU for network device vlan22: No such device 2025-09-30T20:24:14.467Z|00041|bridge|INFO|bridge br-ex: added interface vlan22 on port 2 2025-09-30T20:24:14.478Z|00042|netdev|WARN|failed to set MTU for network device vlan20: No such device 2025-09-30T20:24:14.479Z|00043|bridge|INFO|bridge br-ex: added interface vlan20 on port 3 2025-09-30T20:24:14.488Z|00044|netdev|WARN|failed to set MTU for network device vlan21: No such device 2025-09-30T20:24:14.489Z|00045|bridge|INFO|bridge br-ex: added interface vlan21 on port 4 2025-09-30T20:24:14.490Z|00001|odp_util(revalidator8)|WARN|invalid Ethertype 0 in flow key 2025-09-30T20:24:14.490Z|00002|odp_util(revalidator8)|WARN|the flow key in error is: recirc_id(0),dp_hash(0),skb_priority(0),in_port(2),skb_mark(0),ct_state(0),ct_zone(0),ct_mark(0),ct_label(0),eth(src=fe:54:00:2b:cc:b1,dst=01:80:c2:00:00:00),eth_type(0x0000) 2025-09-30T20:28:32.183Z|00046|bridge|INFO|bridge br-ex: deleted interface br-ex on port 65534 2025-09-30T20:28:32.446Z|00047|bridge|INFO|bridge br-ex: deleted interface enp1s0 on port 1 2025-09-30T20:28:32.446Z|00048|bridge|INFO|bridge br-ex: deleted interface vlan22 on port 2 2025-09-30T20:28:32.446Z|00049|bridge|INFO|bridge br-ex: deleted interface vlan21 on port 4 2025-09-30T20:28:32.446Z|00050|bridge|INFO|bridge br-ex: deleted interface vlan20 on port 3 2025-09-30T20:29:02.104Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2025-09-30T20:29:02.342Z|00002|ovs_numa|INFO|Discovered 6 CPU cores on NUMA node 0 2025-09-30T20:29:02.342Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 6 CPU cores 2025-09-30T20:29:02.343Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2025-09-30T20:29:02.343Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2025-09-30T20:29:02.345Z|00006|dpdk|INFO|DPDK Disabled - Use other_config:dpdk-init to enable 2025-09-30T20:29:02.354Z|00007|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2025-09-30T20:29:02.355Z|00008|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2025-09-30T20:29:02.356Z|00009|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2025-09-30T20:29:02.356Z|00010|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2025-09-30T20:29:02.356Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2025-09-30T20:29:02.356Z|00012|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2025-09-30T20:29:02.356Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2025-09-30T20:29:02.356Z|00014|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2025-09-30T20:29:02.357Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2025-09-30T20:29:02.357Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2025-09-30T20:29:02.357Z|00017|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2025-09-30T20:29:02.357Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2025-09-30T20:29:02.358Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2025-09-30T20:29:02.358Z|00020|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2025-09-30T20:29:02.358Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2025-09-30T20:29:02.358Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2025-09-30T20:29:02.358Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2025-09-30T20:29:02.358Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2025-09-30T20:29:02.358Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2025-09-30T20:29:02.358Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2025-09-30T20:29:02.358Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2025-09-30T20:29:02.358Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2025-09-30T20:29:02.358Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2025-09-30T20:29:02.359Z|00030|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 6, setting n-revalidator-threads to 2 2025-09-30T20:29:02.359Z|00031|ofproto_dpif_upcall|INFO|Starting 8 threads 2025-09-30T20:29:02.385Z|00032|bridge|INFO|bridge br-ex: added interface enp1s0 on port 1 2025-09-30T20:29:02.392Z|00033|netdev|WARN|failed to set MTU for network device vlan22: No such device 2025-09-30T20:29:02.393Z|00034|bridge|INFO|bridge br-ex: added interface vlan22 on port 2 2025-09-30T20:29:02.400Z|00035|netdev|WARN|failed to set MTU for network device vlan20: No such device 2025-09-30T20:29:02.401Z|00036|bridge|INFO|bridge br-ex: added interface vlan20 on port 3 2025-09-30T20:29:02.409Z|00037|netdev|WARN|failed to set MTU for network device vlan21: No such device 2025-09-30T20:29:02.411Z|00038|bridge|INFO|bridge br-ex: added interface vlan21 on port 4 2025-09-30T20:29:02.411Z|00039|bridge|INFO|bridge br-ex: using datapath ID 00005254002bccb1 2025-09-30T20:29:02.411Z|00040|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2025-09-30T20:29:02.417Z|00041|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.5-115.el9s 2025-09-30T20:29:02.872Z|00042|bridge|INFO|bridge br-ex: deleted interface vlan21 on port 4 2025-09-30T20:29:02.893Z|00043|bridge|INFO|bridge br-ex: deleted interface enp1s0 on port 1 2025-09-30T20:29:02.893Z|00044|bridge|INFO|bridge br-ex: deleted interface vlan22 on port 2 2025-09-30T20:29:02.893Z|00045|bridge|INFO|bridge br-ex: deleted interface vlan20 on port 3 2025-09-30T20:29:02.965Z|00046|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2025-09-30T20:29:02.965Z|00047|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2025-09-30T20:29:02.965Z|00048|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2025-09-30T20:29:02.965Z|00049|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2025-09-30T20:29:02.966Z|00050|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2025-09-30T20:29:02.966Z|00051|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2025-09-30T20:29:02.966Z|00052|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2025-09-30T20:29:02.966Z|00053|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2025-09-30T20:29:02.966Z|00054|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2025-09-30T20:29:02.966Z|00055|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2025-09-30T20:29:02.966Z|00056|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2025-09-30T20:29:02.966Z|00057|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2025-09-30T20:29:02.966Z|00058|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2025-09-30T20:29:02.966Z|00059|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2025-09-30T20:29:02.966Z|00060|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2025-09-30T20:29:02.966Z|00061|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2025-09-30T20:29:02.967Z|00062|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2025-09-30T20:29:02.967Z|00063|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2025-09-30T20:29:02.967Z|00064|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2025-09-30T20:29:02.967Z|00065|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2025-09-30T20:29:02.967Z|00066|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2025-09-30T20:29:02.967Z|00067|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2025-09-30T20:29:02.967Z|00068|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2025-09-30T20:29:02.967Z|00069|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 6, setting n-revalidator-threads to 2 2025-09-30T20:29:02.967Z|00070|ofproto_dpif_upcall|INFO|Starting 8 threads 2025-09-30T20:29:02.984Z|00071|netdev|WARN|failed to set MTU for network device vlan21: No such device 2025-09-30T20:29:02.986Z|00072|bridge|INFO|bridge br-ex: added interface vlan21 on port 1 2025-09-30T20:29:02.986Z|00073|bridge|INFO|bridge br-ex: using datapath ID 00005254002bccb1 2025-09-30T20:29:02.986Z|00074|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2025-09-30T20:29:02.996Z|00075|netdev|WARN|failed to set MTU for network device br-ex: No such device 2025-09-30T20:29:02.998Z|00076|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2025-09-30T20:29:03.000Z|00077|bridge|INFO|bridge br-ex: added interface enp1s0 on port 2 2025-09-30T20:29:03.006Z|00078|netdev|WARN|failed to set MTU for network device vlan22: No such device 2025-09-30T20:29:03.008Z|00079|bridge|INFO|bridge br-ex: added interface vlan22 on port 3 2025-09-30T20:29:03.015Z|00080|netdev|WARN|failed to set MTU for network device vlan20: No such device 2025-09-30T20:29:03.017Z|00081|bridge|INFO|bridge br-ex: added interface vlan20 on port 4 2025-09-30T20:29:12.421Z|00082|memory|INFO|275520 kB peak resident set size after 10.3 seconds 2025-09-30T20:29:12.422Z|00083|memory|INFO|handlers:6 idl-cells-Open_vSwitch:324 ports:5 revalidators:2 rules:5 udpif keys:16 2025-09-30T20:31:48.023Z|00084|bridge|INFO|bridge br-int: added interface br-int on port 65534 2025-09-30T20:31:48.024Z|00085|bridge|INFO|bridge br-int: using datapath ID 0000022e83cf435f 2025-09-30T20:31:48.024Z|00086|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2025-09-30T20:31:48.066Z|00087|bridge|INFO|bridge br-int: added interface ovn-c65e23-0 on port 1 2025-09-30T20:32:06.040Z|00088|connmgr|INFO|br-int<->unix#1: 21 flow_mods 10 s ago (20 adds, 1 deletes)