2026-01-21T17:53:17.562Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-01-21T17:53:17.648Z|00002|ovs_numa|INFO|Discovered 6 CPU cores on NUMA node 0 2026-01-21T17:53:17.648Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 6 CPU cores 2026-01-21T17:53:17.649Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-01-21T17:53:17.649Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-01-21T17:53:17.651Z|00006|dpdk|INFO|DPDK Disabled - Use other_config:dpdk-init to enable 2026-01-21T17:53:17.658Z|00007|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.5-115.el9s 2026-01-21T18:03:06.128Z|00008|memory|INFO|255600 kB peak resident set size after 586.6 seconds 2026-01-21T18:03:06.128Z|00009|memory|INFO|idl-cells-Open_vSwitch:17 2026-01-21T18:03:06.132Z|00010|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-01-21T18:03:06.132Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-01-21T18:03:06.132Z|00012|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-01-21T18:03:06.132Z|00013|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-01-21T18:03:06.132Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-01-21T18:03:06.132Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-01-21T18:03:06.132Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-01-21T18:03:06.133Z|00017|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-01-21T18:03:06.133Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-01-21T18:03:06.133Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-01-21T18:03:06.133Z|00020|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-01-21T18:03:06.133Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-01-21T18:03:06.135Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-01-21T18:03:06.135Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-01-21T18:03:06.135Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-01-21T18:03:06.135Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-01-21T18:03:06.135Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-01-21T18:03:06.135Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-01-21T18:03:06.135Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-01-21T18:03:06.135Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-01-21T18:03:06.135Z|00030|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-01-21T18:03:06.135Z|00031|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-01-21T18:03:06.135Z|00032|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-01-21T18:03:06.136Z|00033|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 6, setting n-revalidator-threads to 2 2026-01-21T18:03:06.136Z|00034|ofproto_dpif_upcall|INFO|Starting 8 threads 2026-01-21T18:03:06.185Z|00035|netdev|WARN|failed to set MTU for network device br-ex: No such device 2026-01-21T18:03:06.189Z|00036|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2026-01-21T18:03:06.189Z|00037|bridge|INFO|bridge br-ex: using datapath ID 00005254006ed44e 2026-01-21T18:03:06.189Z|00038|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-01-21T18:03:06.196Z|00039|bridge|INFO|bridge br-ex: added interface enp1s0 on port 1 2026-01-21T18:03:06.207Z|00040|netdev|WARN|failed to set MTU for network device vlan22: No such device 2026-01-21T18:03:06.209Z|00041|bridge|INFO|bridge br-ex: added interface vlan22 on port 2 2026-01-21T18:03:06.216Z|00042|netdev|WARN|failed to set MTU for network device vlan21: No such device 2026-01-21T18:03:06.218Z|00043|bridge|INFO|bridge br-ex: added interface vlan21 on port 3 2026-01-21T18:03:06.229Z|00044|netdev|WARN|failed to set MTU for network device vlan20: No such device 2026-01-21T18:03:06.235Z|00045|bridge|INFO|bridge br-ex: added interface vlan20 on port 4 2026-01-21T18:03:06.235Z|00001|ofproto_dpif_upcall(handler7)|INFO|received packet on unassociated datapath port 3 (no OpenFlow port for datapath port 3) 2026-01-21T18:06:11.896Z|00046|bridge|INFO|bridge br-ex: deleted interface br-ex on port 65534 2026-01-21T18:06:12.069Z|00047|bridge|INFO|bridge br-ex: deleted interface enp1s0 on port 1 2026-01-21T18:06:12.069Z|00048|bridge|INFO|bridge br-ex: deleted interface vlan22 on port 2 2026-01-21T18:06:12.069Z|00049|bridge|INFO|bridge br-ex: deleted interface vlan20 on port 4 2026-01-21T18:06:12.069Z|00050|bridge|INFO|bridge br-ex: deleted interface vlan21 on port 3 2026-01-21T18:06:37.921Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-01-21T18:06:38.020Z|00002|ovs_numa|INFO|Discovered 6 CPU cores on NUMA node 0 2026-01-21T18:06:38.020Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 6 CPU cores 2026-01-21T18:06:38.021Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-01-21T18:06:38.021Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-01-21T18:06:38.023Z|00006|dpdk|INFO|DPDK Disabled - Use other_config:dpdk-init to enable 2026-01-21T18:06:38.038Z|00007|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-01-21T18:06:38.039Z|00008|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-01-21T18:06:38.039Z|00009|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-01-21T18:06:38.039Z|00010|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-01-21T18:06:38.039Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-01-21T18:06:38.039Z|00012|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-01-21T18:06:38.039Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-01-21T18:06:38.039Z|00014|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-01-21T18:06:38.039Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-01-21T18:06:38.039Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-01-21T18:06:38.039Z|00017|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-01-21T18:06:38.039Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-01-21T18:06:38.040Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-01-21T18:06:38.040Z|00020|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-01-21T18:06:38.040Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-01-21T18:06:38.040Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-01-21T18:06:38.040Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-01-21T18:06:38.040Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-01-21T18:06:38.040Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-01-21T18:06:38.040Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-01-21T18:06:38.040Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-01-21T18:06:38.040Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-01-21T18:06:38.040Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-01-21T18:06:38.040Z|00030|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 6, setting n-revalidator-threads to 2 2026-01-21T18:06:38.040Z|00031|ofproto_dpif_upcall|INFO|Starting 8 threads 2026-01-21T18:06:38.063Z|00032|bridge|INFO|bridge br-ex: added interface enp1s0 on port 1 2026-01-21T18:06:38.070Z|00033|netdev|WARN|failed to set MTU for network device vlan22: No such device 2026-01-21T18:06:38.075Z|00034|bridge|INFO|bridge br-ex: added interface vlan22 on port 2 2026-01-21T18:06:38.081Z|00035|netdev|WARN|failed to set MTU for network device vlan21: No such device 2026-01-21T18:06:38.082Z|00036|bridge|INFO|bridge br-ex: added interface vlan21 on port 3 2026-01-21T18:06:38.088Z|00037|netdev|WARN|failed to set MTU for network device vlan20: No such device 2026-01-21T18:06:38.090Z|00038|bridge|INFO|bridge br-ex: added interface vlan20 on port 4 2026-01-21T18:06:38.090Z|00039|bridge|INFO|bridge br-ex: using datapath ID 00005254006ed44e 2026-01-21T18:06:38.090Z|00040|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-01-21T18:06:38.095Z|00041|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.5-115.el9s 2026-01-21T18:06:38.370Z|00042|bridge|INFO|bridge br-ex: deleted interface vlan21 on port 3 2026-01-21T18:06:38.396Z|00043|bridge|INFO|bridge br-ex: deleted interface enp1s0 on port 1 2026-01-21T18:06:38.396Z|00044|bridge|INFO|bridge br-ex: deleted interface vlan22 on port 2 2026-01-21T18:06:38.396Z|00045|bridge|INFO|bridge br-ex: deleted interface vlan20 on port 4 2026-01-21T18:06:38.480Z|00046|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-01-21T18:06:38.480Z|00047|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-01-21T18:06:38.480Z|00048|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-01-21T18:06:38.480Z|00049|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-01-21T18:06:38.480Z|00050|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-01-21T18:06:38.480Z|00051|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-01-21T18:06:38.480Z|00052|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-01-21T18:06:38.481Z|00053|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-01-21T18:06:38.481Z|00054|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-01-21T18:06:38.481Z|00055|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-01-21T18:06:38.481Z|00056|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-01-21T18:06:38.481Z|00057|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-01-21T18:06:38.483Z|00058|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-01-21T18:06:38.483Z|00059|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-01-21T18:06:38.483Z|00060|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-01-21T18:06:38.483Z|00061|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-01-21T18:06:38.483Z|00062|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-01-21T18:06:38.483Z|00063|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-01-21T18:06:38.484Z|00064|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-01-21T18:06:38.484Z|00065|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-01-21T18:06:38.484Z|00066|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-01-21T18:06:38.484Z|00067|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-01-21T18:06:38.484Z|00068|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-01-21T18:06:38.486Z|00069|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 6, setting n-revalidator-threads to 2 2026-01-21T18:06:38.486Z|00070|ofproto_dpif_upcall|INFO|Starting 8 threads 2026-01-21T18:06:38.499Z|00071|netdev|WARN|failed to set MTU for network device vlan21: No such device 2026-01-21T18:06:38.502Z|00072|bridge|INFO|bridge br-ex: added interface vlan21 on port 1 2026-01-21T18:06:38.502Z|00073|bridge|INFO|bridge br-ex: using datapath ID 00005254006ed44e 2026-01-21T18:06:38.502Z|00074|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-01-21T18:06:38.510Z|00075|bridge|INFO|bridge br-ex: added interface enp1s0 on port 2 2026-01-21T18:06:38.516Z|00076|netdev|WARN|failed to set MTU for network device vlan22: No such device 2026-01-21T18:06:38.517Z|00077|bridge|INFO|bridge br-ex: added interface vlan22 on port 3 2026-01-21T18:06:38.523Z|00078|netdev|WARN|failed to set MTU for network device vlan20: No such device 2026-01-21T18:06:38.525Z|00079|bridge|INFO|bridge br-ex: added interface vlan20 on port 4 2026-01-21T18:06:38.707Z|00080|netdev|WARN|failed to set MTU for network device br-ex: No such device 2026-01-21T18:06:38.709Z|00081|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2026-01-21T18:06:48.098Z|00082|memory|INFO|275600 kB peak resident set size after 10.2 seconds 2026-01-21T18:06:48.098Z|00083|memory|INFO|handlers:6 idl-cells-Open_vSwitch:324 ports:5 revalidators:2 rules:5 udpif keys:17 2026-01-21T18:09:18.093Z|00084|bridge|INFO|bridge br-int: added interface br-int on port 65534 2026-01-21T18:09:18.093Z|00085|bridge|INFO|bridge br-int: using datapath ID 00006e07b901066f 2026-01-21T18:09:18.094Z|00086|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2026-01-21T18:09:18.149Z|00087|bridge|INFO|bridge br-int: added interface ovn-9abb34-0 on port 1 2026-01-21T18:09:36.117Z|00088|connmgr|INFO|br-int<->unix#1: 21 flow_mods 10 s ago (20 adds, 1 deletes) 2026-01-21T18:27:37.581Z|00089|bridge|INFO|bridge br-int: deleted interface ovn-9abb34-0 on port 1 2026-01-21T18:27:47.582Z|00090|connmgr|INFO|br-int<->unix#1: 3 flow_mods 10 s ago (3 deletes) 2026-01-21T18:28:21.746Z|00091|bridge|INFO|bridge br-int: added interface ovn-9abb34-0 on port 2 2026-01-21T18:28:47.582Z|00092|connmgr|INFO|br-int<->unix#1: 3 flow_mods 25 s ago (3 adds) 2026-01-21T18:31:03.360Z|00093|connmgr|INFO|br-int<->unix#46: 21 flow_mods 10 s ago (20 adds, 1 deletes) 2026-01-21T18:41:53.373Z|00094|rconn|ERR|br-int<->unix#46: no response to inactivity probe after 60 seconds, disconnecting 2026-01-21T18:44:56.116Z|00095|rconn|ERR|br-int<->unix#45: no response to inactivity probe after 60 seconds, disconnecting 2026-01-21T18:44:57.119Z|00096|rconn|ERR|br-int<->unix#67: no response to inactivity probe after 60 seconds, disconnecting 2026-01-21T18:47:03.304Z|00097|rconn|ERR|br-int<->unix#68: no response to inactivity probe after 60 seconds, disconnecting 2026-01-21T18:47:03.304Z|00098|rconn|ERR|br-int<->unix#69: no response to inactivity probe after 60 seconds, disconnecting