2026-02-27T01:28:29.461Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-02-27T01:28:29.527Z|00002|ovs_numa|INFO|Discovered 2 CPU cores on NUMA node 0 2026-02-27T01:28:29.527Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 2 CPU cores 2026-02-27T01:28:29.533Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-02-27T01:28:29.534Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-02-27T01:28:29.536Z|00006|dpdk|INFO|DPDK Disabled - Use other_config:dpdk-init to enable 2026-02-27T01:28:29.542Z|00007|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.5-115.el9s 2026-02-27T01:37:39.674Z|00008|memory|INFO|255748 kB peak resident set size after 550.2 seconds 2026-02-27T01:37:39.674Z|00009|memory|INFO|idl-cells-Open_vSwitch:17 2026-02-27T01:37:39.685Z|00010|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-02-27T01:37:39.685Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-02-27T01:37:39.685Z|00012|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-02-27T01:37:39.685Z|00013|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-02-27T01:37:39.685Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-02-27T01:37:39.685Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-02-27T01:37:39.685Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-02-27T01:37:39.685Z|00017|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-02-27T01:37:39.685Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-02-27T01:37:39.685Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-02-27T01:37:39.685Z|00020|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-02-27T01:37:39.685Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-02-27T01:37:39.691Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-02-27T01:37:39.691Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-02-27T01:37:39.692Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-02-27T01:37:39.692Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-02-27T01:37:39.692Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-02-27T01:37:39.692Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-02-27T01:37:39.692Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-02-27T01:37:39.692Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-02-27T01:37:39.692Z|00030|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-02-27T01:37:39.692Z|00031|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-02-27T01:37:39.692Z|00032|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-02-27T01:37:39.692Z|00033|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 2, setting n-revalidator-threads to 1 2026-02-27T01:37:39.692Z|00034|ofproto_dpif_upcall|INFO|Starting 3 threads 2026-02-27T01:37:39.750Z|00035|netdev|WARN|failed to set MTU for network device br-ex: No such device 2026-02-27T01:37:39.755Z|00036|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2026-02-27T01:37:39.755Z|00037|bridge|INFO|bridge br-ex: using datapath ID 0000525400f1cdcf 2026-02-27T01:37:39.756Z|00038|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-02-27T01:37:39.763Z|00039|bridge|INFO|bridge br-ex: added interface enp1s0 on port 1 2026-02-27T01:37:39.783Z|00040|netdev|WARN|failed to set MTU for network device vlan22: No such device 2026-02-27T01:37:39.789Z|00041|bridge|INFO|bridge br-ex: added interface vlan22 on port 2 2026-02-27T01:37:39.809Z|00042|netdev|WARN|failed to set MTU for network device vlan20: No such device 2026-02-27T01:37:39.810Z|00043|bridge|INFO|bridge br-ex: added interface vlan20 on port 3 2026-02-27T01:37:39.817Z|00001|ofproto_dpif_upcall(handler1)|INFO|received packet on unassociated datapath port 3 (no OpenFlow port for datapath port 3) 2026-02-27T01:37:39.835Z|00044|netdev|WARN|failed to set MTU for network device vlan21: No such device 2026-02-27T01:37:39.836Z|00045|bridge|INFO|bridge br-ex: added interface vlan21 on port 4 2026-02-27T01:40:51.119Z|00046|bridge|INFO|bridge br-ex: deleted interface br-ex on port 65534 2026-02-27T01:40:51.276Z|00047|bridge|INFO|bridge br-ex: deleted interface enp1s0 on port 1 2026-02-27T01:40:51.276Z|00048|bridge|INFO|bridge br-ex: deleted interface vlan22 on port 2 2026-02-27T01:40:51.276Z|00049|bridge|INFO|bridge br-ex: deleted interface vlan21 on port 4 2026-02-27T01:40:51.276Z|00050|bridge|INFO|bridge br-ex: deleted interface vlan20 on port 3 2026-02-27T01:41:19.886Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-02-27T01:41:20.026Z|00002|ovs_numa|INFO|Discovered 2 CPU cores on NUMA node 0 2026-02-27T01:41:20.026Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 2 CPU cores 2026-02-27T01:41:20.026Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-02-27T01:41:20.026Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-02-27T01:41:20.031Z|00006|dpdk|INFO|DPDK Disabled - Use other_config:dpdk-init to enable 2026-02-27T01:41:20.046Z|00007|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-02-27T01:41:20.046Z|00008|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-02-27T01:41:20.047Z|00009|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-02-27T01:41:20.047Z|00010|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-02-27T01:41:20.047Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-02-27T01:41:20.047Z|00012|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-02-27T01:41:20.047Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-02-27T01:41:20.047Z|00014|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-02-27T01:41:20.047Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-02-27T01:41:20.047Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-02-27T01:41:20.047Z|00017|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-02-27T01:41:20.047Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-02-27T01:41:20.049Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-02-27T01:41:20.049Z|00020|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-02-27T01:41:20.049Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-02-27T01:41:20.049Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-02-27T01:41:20.049Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-02-27T01:41:20.049Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-02-27T01:41:20.049Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-02-27T01:41:20.049Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-02-27T01:41:20.049Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-02-27T01:41:20.049Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-02-27T01:41:20.049Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-02-27T01:41:20.049Z|00030|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 2, setting n-revalidator-threads to 1 2026-02-27T01:41:20.049Z|00031|ofproto_dpif_upcall|INFO|Starting 3 threads 2026-02-27T01:41:20.079Z|00032|bridge|INFO|bridge br-ex: added interface enp1s0 on port 1 2026-02-27T01:41:20.086Z|00033|netdev|WARN|failed to set MTU for network device vlan22: No such device 2026-02-27T01:41:20.087Z|00034|bridge|INFO|bridge br-ex: added interface vlan22 on port 2 2026-02-27T01:41:20.093Z|00035|netdev|WARN|failed to set MTU for network device vlan20: No such device 2026-02-27T01:41:20.098Z|00036|bridge|INFO|bridge br-ex: added interface vlan20 on port 3 2026-02-27T01:41:20.104Z|00037|netdev|WARN|failed to set MTU for network device vlan21: No such device 2026-02-27T01:41:20.106Z|00038|bridge|INFO|bridge br-ex: added interface vlan21 on port 4 2026-02-27T01:41:20.106Z|00039|bridge|INFO|bridge br-ex: using datapath ID 0000525400f1cdcf 2026-02-27T01:41:20.106Z|00040|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-02-27T01:41:20.115Z|00041|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.5-115.el9s 2026-02-27T01:41:20.471Z|00042|bridge|INFO|bridge br-ex: deleted interface enp1s0 on port 1 2026-02-27T01:41:20.492Z|00043|bridge|INFO|bridge br-ex: deleted interface vlan22 on port 2 2026-02-27T01:41:20.519Z|00044|bridge|INFO|bridge br-ex: deleted interface vlan21 on port 4 2026-02-27T01:41:20.519Z|00045|bridge|INFO|bridge br-ex: deleted interface vlan20 on port 3 2026-02-27T01:41:20.624Z|00046|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-02-27T01:41:20.625Z|00047|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-02-27T01:41:20.625Z|00048|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-02-27T01:41:20.625Z|00049|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-02-27T01:41:20.625Z|00050|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-02-27T01:41:20.625Z|00051|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-02-27T01:41:20.625Z|00052|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-02-27T01:41:20.625Z|00053|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-02-27T01:41:20.625Z|00054|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-02-27T01:41:20.626Z|00055|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-02-27T01:41:20.626Z|00056|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-02-27T01:41:20.626Z|00057|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-02-27T01:41:20.626Z|00058|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-02-27T01:41:20.626Z|00059|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-02-27T01:41:20.626Z|00060|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-02-27T01:41:20.626Z|00061|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-02-27T01:41:20.626Z|00062|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-02-27T01:41:20.626Z|00063|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-02-27T01:41:20.626Z|00064|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-02-27T01:41:20.626Z|00065|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-02-27T01:41:20.627Z|00066|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-02-27T01:41:20.627Z|00067|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-02-27T01:41:20.627Z|00068|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-02-27T01:41:20.627Z|00069|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 2, setting n-revalidator-threads to 1 2026-02-27T01:41:20.627Z|00070|ofproto_dpif_upcall|INFO|Starting 3 threads 2026-02-27T01:41:20.650Z|00071|netdev|WARN|failed to set MTU for network device br-ex: No such device 2026-02-27T01:41:20.651Z|00072|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2026-02-27T01:41:20.652Z|00073|bridge|INFO|bridge br-ex: using datapath ID 0000525400f1cdcf 2026-02-27T01:41:20.652Z|00074|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-02-27T01:41:20.687Z|00075|netdev|WARN|failed to set MTU for network device vlan20: No such device 2026-02-27T01:41:20.688Z|00076|bridge|INFO|bridge br-ex: added interface vlan20 on port 1 2026-02-27T01:41:20.692Z|00077|bridge|INFO|bridge br-ex: added interface enp1s0 on port 2 2026-02-27T01:41:20.717Z|00078|netdev|WARN|failed to set MTU for network device vlan22: No such device 2026-02-27T01:41:20.719Z|00079|bridge|INFO|bridge br-ex: added interface vlan22 on port 3 2026-02-27T01:41:20.741Z|00080|netdev|WARN|failed to set MTU for network device vlan21: No such device 2026-02-27T01:41:20.743Z|00081|bridge|INFO|bridge br-ex: added interface vlan21 on port 4 2026-02-27T01:41:30.117Z|00082|memory|INFO|265096 kB peak resident set size after 10.2 seconds 2026-02-27T01:41:30.118Z|00083|memory|INFO|handlers:2 idl-cells-Open_vSwitch:324 ports:5 revalidators:1 rules:5 udpif keys:16 2026-02-27T01:44:08.290Z|00084|bridge|INFO|bridge br-int: added interface br-int on port 65534 2026-02-27T01:44:08.290Z|00085|bridge|INFO|bridge br-int: using datapath ID 00004636c7b7c026 2026-02-27T01:44:08.291Z|00086|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2026-02-27T01:44:08.345Z|00087|bridge|INFO|bridge br-int: added interface ovn-2d8067-0 on port 1 2026-02-27T01:44:26.313Z|00088|connmgr|INFO|br-int<->unix#1: 21 flow_mods 10 s ago (20 adds, 1 deletes) 2026-02-27T02:07:13.502Z|00089|connmgr|INFO|br-int<->unix#48: 21 flow_mods 10 s ago (20 adds, 1 deletes)