2025-10-14T07:13:08.442Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2025-10-14T07:13:08.497Z|00002|ovs_numa|INFO|Discovered 8 CPU cores on NUMA node 0 2025-10-14T07:13:08.497Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 8 CPU cores 2025-10-14T07:13:08.497Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2025-10-14T07:13:08.497Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2025-10-14T07:13:08.499Z|00006|dpdk|INFO|DPDK Disabled - Use other_config:dpdk-init to enable 2025-10-14T07:13:08.505Z|00007|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.5-110.el9fdp 2025-10-14T07:13:10.254Z|00008|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2025-10-14T07:13:10.254Z|00009|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2025-10-14T07:13:10.254Z|00010|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2025-10-14T07:13:10.254Z|00011|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2025-10-14T07:13:10.254Z|00012|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2025-10-14T07:13:10.254Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2025-10-14T07:13:10.254Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2025-10-14T07:13:10.255Z|00015|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2025-10-14T07:13:10.255Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2025-10-14T07:13:10.255Z|00017|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2025-10-14T07:13:10.255Z|00018|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 0 2025-10-14T07:13:10.255Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2025-10-14T07:13:10.258Z|00020|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2025-10-14T07:13:10.258Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2025-10-14T07:13:10.258Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2025-10-14T07:13:10.258Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2025-10-14T07:13:10.258Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2025-10-14T07:13:10.258Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2025-10-14T07:13:10.258Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2025-10-14T07:13:10.258Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2025-10-14T07:13:10.258Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2025-10-14T07:13:10.258Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2025-10-14T07:13:10.258Z|00030|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2025-10-14T07:13:10.259Z|00031|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 8, setting n-revalidator-threads to 3 2025-10-14T07:13:10.259Z|00032|ofproto_dpif_upcall|INFO|Starting 11 threads 2025-10-14T07:13:10.297Z|00033|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2025-10-14T07:13:10.297Z|00034|bridge|INFO|bridge br-ex: using datapath ID 0000fa163e5a616f 2025-10-14T07:13:10.297Z|00035|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2025-10-14T07:13:15.758Z|00036|bridge|INFO|bridge br-ex: added interface eth1 on port 1 2025-10-14T07:13:15.920Z|00037|bridge|INFO|bridge br-ex: added interface vlan20 on port 2 2025-10-14T07:13:18.479Z|00038|memory|INFO|273056 kB peak resident set size after 10.0 seconds 2025-10-14T07:13:18.479Z|00039|memory|INFO|handlers:8 idl-cells-Open_vSwitch:210 ports:3 revalidators:3 rules:5 udpif keys:29 2025-10-14T07:13:19.211Z|00040|bridge|INFO|bridge br-ex: added interface vlan23 on port 3 2025-10-14T07:13:22.517Z|00041|bridge|INFO|bridge br-ex: added interface vlan22 on port 4 2025-10-14T07:13:25.831Z|00042|bridge|INFO|bridge br-ex: added interface vlan21 on port 5 2025-10-14T07:13:29.114Z|00043|bridge|INFO|bridge br-ex: added interface vlan44 on port 6 2025-10-14T07:57:45.497Z|00044|bridge|INFO|bridge br-int: added interface br-int on port 65534 2025-10-14T07:57:45.497Z|00045|bridge|INFO|bridge br-int: using datapath ID 0000be291ae8097a 2025-10-14T07:57:45.497Z|00046|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2025-10-14T07:58:04.512Z|00047|connmgr|INFO|br-int<->unix#1: 18 flow_mods 10 s ago (17 adds, 1 deletes) 2025-10-14T08:17:43.959Z|00048|bridge|INFO|bridge br-int: added interface ovn-93d451-0 on port 1 2025-10-14T08:17:53.963Z|00049|connmgr|INFO|br-int<->unix#1: 3 flow_mods 10 s ago (3 adds) 2025-10-14T08:37:45.706Z|00050|bridge|INFO|bridge br-int: added interface ovn-7f1701-0 on port 2 2025-10-14T08:37:55.708Z|00051|connmgr|INFO|br-int<->unix#1: 3 flow_mods 10 s ago (3 adds) 2025-10-14T08:45:01.157Z|00052|bridge|INFO|bridge br-ex: added interface patch-provnet-c2489609-b3bc-46cc-a633-50839c031a1b-to-br-int on port 7 2025-10-14T08:45:01.158Z|00053|bridge|INFO|bridge br-int: added interface patch-br-int-to-provnet-c2489609-b3bc-46cc-a633-50839c031a1b on port 3 2025-10-14T08:45:01.158Z|00054|bfd|INFO|ovn-7f1701-0: BFD state change: (bfd.SessionState: admin_down, bfd.LocalDiag: "No Diagnostic") -> (bfd.SessionState: down, bfd.LocalDiag: "No Diagnostic") Forwarding: false Detect Multiplier: 3 Concatenated Path Down: false TX Interval: Approx 1000ms RX Interval: Approx 0ms Detect Time: now -7548347ms Next TX Time: now -7548347ms Last TX Time: now -7548347ms Local Flags: none Local Session State: admin_down Local Diagnostic: No Diagnostic Local Discriminator: 0x8c5caa5b Local Minimum TX Interval: 1000ms Local Minimum RX Interval: 0ms Remote Flags: none Remote Session State: admin_down Remote Diagnostic: No Diagnostic Remote Discriminator: 0x0 Remote Minimum TX Interval: 0ms Remote Minimum RX Interval: 0ms Remote Detect Multiplier: 0 2025-10-14T08:45:01.160Z|00055|bfd|INFO|ovn-93d451-0: BFD state change: (bfd.SessionState: admin_down, bfd.LocalDiag: "No Diagnostic") -> (bfd.SessionState: down, bfd.LocalDiag: "No Diagnostic") Forwarding: false Detect Multiplier: 3 Concatenated Path Down: false TX Interval: Approx 1000ms RX Interval: Approx 0ms Detect Time: now -7548349ms Next TX Time: now -7548349ms Last TX Time: now -7548349ms Local Flags: none Local Session State: admin_down Local Diagnostic: No Diagnostic Local Discriminator: 0x3bef1cd0 Local Minimum TX Interval: 1000ms Local Minimum RX Interval: 0ms Remote Flags: none Remote Session State: admin_down Remote Diagnostic: No Diagnostic Remote Discriminator: 0x0 Remote Minimum TX Interval: 0ms Remote Minimum RX Interval: 0ms Remote Detect Multiplier: 0 2025-10-14T08:45:01.160Z|00001|ofproto_dpif_monitor(monitor13)|INFO|monitor thread created 2025-10-14T08:45:02.038Z|00001|bfd(handler6)|INFO|Interface ovn-7f1701-0 remote mult value 0 changed to 3 2025-10-14T08:45:02.038Z|00002|bfd(handler6)|INFO|ovn-7f1701-0: New remote min_rx. vers:1 diag:"No Diagnostic" state:init mult:3 length:24 flags: none my_disc:0xe55be678 your_disc:0x8c5caa5b min_tx:1000000us (1000ms) min_rx:1000000us (1000ms) min_rx_echo:0us (0ms) Forwarding: false Detect Multiplier: 3 Concatenated Path Down: false TX Interval: Approx 1000ms RX Interval: Approx 1000ms Detect Time: now -7549226ms Next TX Time: now -97ms Last TX Time: now -877ms Local Flags: none Local Session State: down Local Diagnostic: No Diagnostic Local Discriminator: 0x8c5caa5b Local Minimum TX Interval: 1000ms Local Minimum RX Interval: 1000ms Remote Flags: none Remote Session State: init Remote Diagnostic: No Diagnostic Remote Discriminator: 0xe55be678 Remote Minimum TX Interval: 0ms Remote Minimum RX Interval: 1000ms Remote Detect Multiplier: 3 2025-10-14T08:45:02.038Z|00003|bfd(handler6)|INFO|ovn-7f1701-0: BFD state change: (bfd.SessionState: down, bfd.LocalDiag: "No Diagnostic") -> (bfd.SessionState: up, bfd.LocalDiag: "No Diagnostic") Forwarding: false Detect Multiplier: 3 Concatenated Path Down: false TX Interval: Approx 1000ms RX Interval: Approx 1000ms Detect Time: now +3000ms Next TX Time: now -97ms Last TX Time: now -877ms Local Flags: none Local Session State: down Local Diagnostic: No Diagnostic Local Discriminator: 0x8c5caa5b Local Minimum TX Interval: 1000ms Local Minimum RX Interval: 1000ms Remote Flags: none Remote Session State: init Remote Diagnostic: No Diagnostic Remote Discriminator: 0xe55be678 Remote Minimum TX Interval: 1000ms Remote Minimum RX Interval: 1000ms Remote Detect Multiplier: 3 2025-10-14T08:45:02.075Z|00004|bfd(handler6)|INFO|Interface ovn-93d451-0 remote mult value 0 changed to 3 2025-10-14T08:45:02.075Z|00005|bfd(handler6)|INFO|ovn-93d451-0: New remote min_rx. vers:1 diag:"No Diagnostic" state:init mult:3 length:24 flags: none my_disc:0xec5d6390 your_disc:0x3bef1cd0 min_tx:1000000us (1000ms) min_rx:1000000us (1000ms) min_rx_echo:0us (0ms) Forwarding: false Detect Multiplier: 3 Concatenated Path Down: false TX Interval: Approx 1000ms RX Interval: Approx 1000ms Detect Time: now -7549264ms Next TX Time: now +955ms Last TX Time: now -15ms Local Flags: none Local Session State: down Local Diagnostic: No Diagnostic Local Discriminator: 0x3bef1cd0 Local Minimum TX Interval: 1000ms Local Minimum RX Interval: 1000ms Remote Flags: none Remote Session State: init Remote Diagnostic: No Diagnostic Remote Discriminator: 0xec5d6390 Remote Minimum TX Interval: 0ms Remote Minimum RX Interval: 1000ms Remote Detect Multiplier: 3 2025-10-14T08:45:02.075Z|00006|bfd(handler6)|INFO|ovn-93d451-0: BFD state change: (bfd.SessionState: down, bfd.LocalDiag: "No Diagnostic") -> (bfd.SessionState: up, bfd.LocalDiag: "No Diagnostic") Forwarding: false Detect Multiplier: 3 Concatenated Path Down: false TX Interval: Approx 1000ms RX Interval: Approx 1000ms Detect Time: now +3000ms Next TX Time: now +955ms Last TX Time: now -15ms Local Flags: none Local Session State: down Local Diagnostic: No Diagnostic Local Discriminator: 0x3bef1cd0 Local Minimum TX Interval: 1000ms Local Minimum RX Interval: 1000ms Remote Flags: none Remote Session State: init Remote Diagnostic: No Diagnostic Remote Discriminator: 0xec5d6390 Remote Minimum TX Interval: 1000ms Remote Minimum RX Interval: 1000ms Remote Detect Multiplier: 3 2025-10-14T08:45:11.166Z|00056|connmgr|INFO|br-int<->unix#1: 485 flow_mods 10 s ago (477 adds, 4 deletes, 4 modifications) 2025-10-14T08:46:11.166Z|00057|connmgr|INFO|br-int<->unix#1: 141 flow_mods in the 29 s starting 54 s ago (124 adds, 17 deletes) 2025-10-14T08:47:11.166Z|00058|connmgr|INFO|br-int<->unix#1: 4 flow_mods 33 s ago (4 adds) 2025-10-14T09:32:21.856Z|00002|bfd(monitor13)|INFO|ovn-7f1701-0: BFD state change: (bfd.SessionState: up, bfd.LocalDiag: "No Diagnostic") -> (bfd.SessionState: down, bfd.LocalDiag: "Control Detection Time Expired") Forwarding: true Detect Multiplier: 3 Concatenated Path Down: false TX Interval: Approx 1000ms RX Interval: Approx 1000ms Detect Time: now +0ms Next TX Time: now +577ms Last TX Time: now -333ms Local Flags: none Local Session State: up Local Diagnostic: No Diagnostic Local Discriminator: 0x8c5caa5b Local Minimum TX Interval: 100ms Local Minimum RX Interval: 1000ms Remote Flags: none Remote Session State: up Remote Diagnostic: No Diagnostic Remote Discriminator: 0xe55be678 Remote Minimum TX Interval: 100ms Remote Minimum RX Interval: 1000ms Remote Detect Multiplier: 3 2025-10-14T09:32:21.889Z|00003|bfd(monitor13)|INFO|ovn-93d451-0: BFD state change: (bfd.SessionState: up, bfd.LocalDiag: "No Diagnostic") -> (bfd.SessionState: down, bfd.LocalDiag: "Control Detection Time Expired") Forwarding: true Detect Multiplier: 3 Concatenated Path Down: false TX Interval: Approx 1000ms RX Interval: Approx 1000ms Detect Time: now +0ms Next TX Time: now +110ms Last TX Time: now -700ms Local Flags: none Local Session State: up Local Diagnostic: No Diagnostic Local Discriminator: 0x3bef1cd0 Local Minimum TX Interval: 100ms Local Minimum RX Interval: 1000ms Remote Flags: none Remote Session State: up Remote Diagnostic: No Diagnostic Remote Discriminator: 0xec5d6390 Remote Minimum TX Interval: 100ms Remote Minimum RX Interval: 1000ms Remote Detect Multiplier: 3