2026-03-19T12:18:03.026Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-03-19T12:18:03.109Z|00002|ovs_numa|INFO|Discovered 2 CPU cores on NUMA node 0 2026-03-19T12:18:03.109Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 2 CPU cores 2026-03-19T12:18:03.109Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-03-19T12:18:03.109Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-03-19T12:18:03.111Z|00006|dpdk|INFO|DPDK Disabled - Use other_config:dpdk-init to enable 2026-03-19T12:18:03.117Z|00007|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.5-115.el9s 2026-03-19T12:22:33.347Z|00008|memory|INFO|252532 kB peak resident set size after 269.1 seconds 2026-03-19T12:22:33.347Z|00009|memory|INFO|idl-cells-Open_vSwitch:17 2026-03-19T12:22:33.353Z|00010|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-03-19T12:22:33.353Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-03-19T12:22:33.353Z|00012|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-03-19T12:22:33.353Z|00013|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-03-19T12:22:33.353Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-03-19T12:22:33.353Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-03-19T12:22:33.353Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-03-19T12:22:33.353Z|00017|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-03-19T12:22:33.353Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-03-19T12:22:33.353Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-03-19T12:22:33.353Z|00020|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-03-19T12:22:33.353Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-03-19T12:22:33.354Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-03-19T12:22:33.354Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-03-19T12:22:33.354Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-03-19T12:22:33.354Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-03-19T12:22:33.354Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-03-19T12:22:33.354Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-03-19T12:22:33.354Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-03-19T12:22:33.354Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-03-19T12:22:33.354Z|00030|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-03-19T12:22:33.354Z|00031|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-03-19T12:22:33.354Z|00032|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-03-19T12:22:33.354Z|00033|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 2, setting n-revalidator-threads to 1 2026-03-19T12:22:33.354Z|00034|ofproto_dpif_upcall|INFO|Starting 3 threads 2026-03-19T12:22:33.451Z|00035|netdev|WARN|failed to set MTU for network device br-ex: No such device 2026-03-19T12:22:33.452Z|00036|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2026-03-19T12:22:33.452Z|00037|bridge|INFO|bridge br-ex: using datapath ID 0000525400250da0 2026-03-19T12:22:33.452Z|00038|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-03-19T12:22:33.472Z|00039|netdev|WARN|failed to set MTU for network device vlan22: No such device 2026-03-19T12:22:33.472Z|00040|bridge|INFO|bridge br-ex: added interface vlan22 on port 1 2026-03-19T12:22:33.499Z|00041|netdev|WARN|failed to set MTU for network device vlan21: No such device 2026-03-19T12:22:33.500Z|00042|bridge|INFO|bridge br-ex: added interface vlan21 on port 2 2026-03-19T12:22:33.522Z|00043|netdev|WARN|failed to set MTU for network device vlan20: No such device 2026-03-19T12:22:33.523Z|00044|bridge|INFO|bridge br-ex: added interface vlan20 on port 3 2026-03-19T12:22:33.524Z|00045|bridge|INFO|bridge br-ex: added interface enp1s0 on port 4 2026-03-19T12:27:36.993Z|00046|bridge|INFO|bridge br-int: added interface br-int on port 65534 2026-03-19T12:27:36.994Z|00047|bridge|INFO|bridge br-int: using datapath ID 00006e522d153f56 2026-03-19T12:27:36.994Z|00048|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2026-03-19T12:27:37.034Z|00049|bridge|INFO|bridge br-int: added interface ovn-2ee38a-0 on port 1 2026-03-19T12:27:55.009Z|00050|connmgr|INFO|br-int<->unix#1: 21 flow_mods 10 s ago (20 adds, 1 deletes)