2026-02-26T18:02:01.709Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-02-26T18:02:01.767Z|00002|ovs_numa|INFO|Discovered 2 CPU cores on NUMA node 0 2026-02-26T18:02:01.767Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 2 CPU cores 2026-02-26T18:02:01.768Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-02-26T18:02:01.768Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-02-26T18:02:01.770Z|00006|dpdk|INFO|DPDK Disabled - Use other_config:dpdk-init to enable 2026-02-26T18:02:01.774Z|00007|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.5-115.el9s 2026-02-26T18:10:47.496Z|00008|memory|INFO|255636 kB peak resident set size after 524.6 seconds 2026-02-26T18:10:47.540Z|00009|memory|INFO|idl-cells-Open_vSwitch:17 2026-02-26T18:10:47.542Z|00010|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-02-26T18:10:47.542Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-02-26T18:10:47.542Z|00012|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-02-26T18:10:47.542Z|00013|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-02-26T18:10:47.542Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-02-26T18:10:47.542Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-02-26T18:10:47.542Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-02-26T18:10:47.543Z|00017|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-02-26T18:10:47.543Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-02-26T18:10:47.543Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-02-26T18:10:47.543Z|00020|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-02-26T18:10:47.543Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-02-26T18:10:47.545Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-02-26T18:10:47.545Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-02-26T18:10:47.545Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-02-26T18:10:47.545Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-02-26T18:10:47.545Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-02-26T18:10:47.545Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-02-26T18:10:47.545Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-02-26T18:10:47.545Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-02-26T18:10:47.545Z|00030|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-02-26T18:10:47.545Z|00031|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-02-26T18:10:47.545Z|00032|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-02-26T18:10:47.545Z|00033|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 2, setting n-revalidator-threads to 1 2026-02-26T18:10:47.545Z|00034|ofproto_dpif_upcall|INFO|Starting 3 threads 2026-02-26T18:10:47.588Z|00035|netdev|WARN|failed to set MTU for network device br-ex: No such device 2026-02-26T18:10:47.589Z|00036|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2026-02-26T18:10:47.589Z|00037|bridge|INFO|bridge br-ex: using datapath ID 000052540023bfb3 2026-02-26T18:10:47.589Z|00038|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-02-26T18:10:47.618Z|00039|netdev|WARN|failed to set MTU for network device vlan22: No such device 2026-02-26T18:10:47.619Z|00040|bridge|INFO|bridge br-ex: added interface vlan22 on port 1 2026-02-26T18:10:47.626Z|00041|netdev|WARN|failed to set MTU for network device vlan20: No such device 2026-02-26T18:10:47.627Z|00042|bridge|INFO|bridge br-ex: added interface vlan20 on port 2 2026-02-26T18:10:47.638Z|00001|ofproto_dpif_upcall(handler2)|INFO|received packet on unassociated datapath port 2 (no OpenFlow port for datapath port 2) 2026-02-26T18:10:47.653Z|00002|ofproto_dpif_upcall(handler2)|INFO|received packet on unassociated datapath port 3 (no OpenFlow port for datapath port 3) 2026-02-26T18:10:47.656Z|00043|netdev|WARN|failed to set MTU for network device vlan21: No such device 2026-02-26T18:10:47.657Z|00044|bridge|INFO|bridge br-ex: added interface vlan21 on port 3 2026-02-26T18:10:47.668Z|00045|bridge|INFO|bridge br-ex: added interface enp1s0 on port 4 2026-02-26T18:13:36.939Z|00046|bridge|INFO|bridge br-ex: deleted interface br-ex on port 65534 2026-02-26T18:13:37.082Z|00047|bridge|INFO|bridge br-ex: deleted interface enp1s0 on port 4 2026-02-26T18:13:37.082Z|00048|bridge|INFO|bridge br-ex: deleted interface vlan22 on port 1 2026-02-26T18:13:37.082Z|00049|bridge|INFO|bridge br-ex: deleted interface vlan21 on port 3 2026-02-26T18:13:37.082Z|00050|bridge|INFO|bridge br-ex: deleted interface vlan20 on port 2 2026-02-26T18:14:02.119Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-02-26T18:14:02.251Z|00002|ovs_numa|INFO|Discovered 2 CPU cores on NUMA node 0 2026-02-26T18:14:02.251Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 2 CPU cores 2026-02-26T18:14:02.252Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-02-26T18:14:02.252Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-02-26T18:14:02.255Z|00006|dpdk|INFO|DPDK Disabled - Use other_config:dpdk-init to enable 2026-02-26T18:14:02.260Z|00007|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-02-26T18:14:02.260Z|00008|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-02-26T18:14:02.260Z|00009|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-02-26T18:14:02.260Z|00010|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-02-26T18:14:02.260Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-02-26T18:14:02.261Z|00012|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-02-26T18:14:02.261Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-02-26T18:14:02.261Z|00014|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-02-26T18:14:02.262Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-02-26T18:14:02.262Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-02-26T18:14:02.262Z|00017|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-02-26T18:14:02.262Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-02-26T18:14:02.263Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-02-26T18:14:02.263Z|00020|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-02-26T18:14:02.263Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-02-26T18:14:02.263Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-02-26T18:14:02.263Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-02-26T18:14:02.263Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-02-26T18:14:02.263Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-02-26T18:14:02.263Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-02-26T18:14:02.263Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-02-26T18:14:02.263Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-02-26T18:14:02.263Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-02-26T18:14:02.263Z|00030|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 2, setting n-revalidator-threads to 1 2026-02-26T18:14:02.263Z|00031|ofproto_dpif_upcall|INFO|Starting 3 threads 2026-02-26T18:14:02.276Z|00032|bridge|INFO|bridge br-ex: added interface enp1s0 on port 4 2026-02-26T18:14:02.282Z|00033|netdev|WARN|failed to set MTU for network device vlan22: No such device 2026-02-26T18:14:02.283Z|00034|bridge|INFO|bridge br-ex: added interface vlan22 on port 1 2026-02-26T18:14:02.290Z|00035|netdev|WARN|failed to set MTU for network device vlan20: No such device 2026-02-26T18:14:02.293Z|00036|bridge|INFO|bridge br-ex: added interface vlan20 on port 2 2026-02-26T18:14:02.298Z|00037|netdev|WARN|failed to set MTU for network device vlan21: No such device 2026-02-26T18:14:02.299Z|00038|bridge|INFO|bridge br-ex: added interface vlan21 on port 3 2026-02-26T18:14:02.299Z|00039|bridge|INFO|bridge br-ex: using datapath ID 000052540023bfb3 2026-02-26T18:14:02.299Z|00040|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-02-26T18:14:02.340Z|00041|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.5-115.el9s 2026-02-26T18:14:02.674Z|00042|bridge|INFO|bridge br-ex: deleted interface vlan22 on port 1 2026-02-26T18:14:02.690Z|00043|bridge|INFO|bridge br-ex: deleted interface vlan21 on port 3 2026-02-26T18:14:02.705Z|00044|bridge|INFO|bridge br-ex: deleted interface enp1s0 on port 4 2026-02-26T18:14:02.705Z|00045|bridge|INFO|bridge br-ex: deleted interface vlan20 on port 2 2026-02-26T18:14:02.804Z|00046|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-02-26T18:14:02.804Z|00047|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-02-26T18:14:02.805Z|00048|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-02-26T18:14:02.805Z|00049|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-02-26T18:14:02.805Z|00050|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-02-26T18:14:02.805Z|00051|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-02-26T18:14:02.805Z|00052|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-02-26T18:14:02.805Z|00053|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-02-26T18:14:02.805Z|00054|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-02-26T18:14:02.805Z|00055|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-02-26T18:14:02.805Z|00056|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-02-26T18:14:02.805Z|00057|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-02-26T18:14:02.811Z|00058|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-02-26T18:14:02.811Z|00059|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-02-26T18:14:02.811Z|00060|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-02-26T18:14:02.811Z|00061|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-02-26T18:14:02.811Z|00062|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-02-26T18:14:02.811Z|00063|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-02-26T18:14:02.811Z|00064|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-02-26T18:14:02.811Z|00065|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-02-26T18:14:02.811Z|00066|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-02-26T18:14:02.811Z|00067|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-02-26T18:14:02.811Z|00068|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-02-26T18:14:02.811Z|00069|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 2, setting n-revalidator-threads to 1 2026-02-26T18:14:02.811Z|00070|ofproto_dpif_upcall|INFO|Starting 3 threads 2026-02-26T18:14:02.837Z|00071|netdev|WARN|failed to set MTU for network device vlan22: No such device 2026-02-26T18:14:02.838Z|00072|bridge|INFO|bridge br-ex: added interface vlan22 on port 1 2026-02-26T18:14:02.838Z|00073|bridge|INFO|bridge br-ex: using datapath ID 000052540023bfb3 2026-02-26T18:14:02.838Z|00074|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-02-26T18:14:02.867Z|00075|netdev|WARN|failed to set MTU for network device vlan20: No such device 2026-02-26T18:14:02.868Z|00076|bridge|INFO|bridge br-ex: added interface vlan20 on port 2 2026-02-26T18:14:02.892Z|00077|netdev|WARN|failed to set MTU for network device vlan21: No such device 2026-02-26T18:14:02.893Z|00078|bridge|INFO|bridge br-ex: added interface vlan21 on port 3 2026-02-26T18:14:02.906Z|00001|ofproto_dpif_upcall(handler8)|INFO|received packet on unassociated datapath port 2 (no OpenFlow port for datapath port 2) 2026-02-26T18:14:02.909Z|00002|ofproto_dpif_upcall(handler8)|INFO|received packet on unassociated datapath port 2 (no OpenFlow port for datapath port 2) 2026-02-26T18:14:02.917Z|00079|bridge|INFO|bridge br-ex: added interface enp1s0 on port 4 2026-02-26T18:14:02.921Z|00080|netdev|WARN|failed to set MTU for network device br-ex: No such device 2026-02-26T18:14:02.922Z|00081|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2026-02-26T18:14:12.343Z|00082|memory|INFO|264996 kB peak resident set size after 10.2 seconds 2026-02-26T18:14:12.343Z|00083|memory|INFO|handlers:2 idl-cells-Open_vSwitch:324 ports:5 revalidators:1 rules:5 udpif keys:18 2026-02-26T18:16:39.731Z|00084|bridge|INFO|bridge br-int: added interface br-int on port 65534 2026-02-26T18:16:39.731Z|00085|bridge|INFO|bridge br-int: using datapath ID 0000b2b3f56d1350 2026-02-26T18:16:39.731Z|00086|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2026-02-26T18:16:39.774Z|00087|bridge|INFO|bridge br-int: added interface ovn-2cbbf5-0 on port 1 2026-02-26T18:16:57.752Z|00088|connmgr|INFO|br-int<->unix#1: 21 flow_mods 10 s ago (20 adds, 1 deletes) 2026-02-26T18:33:38.090Z|00089|bridge|INFO|bridge br-int: deleted interface ovn-2cbbf5-0 on port 1 2026-02-26T18:33:48.090Z|00090|connmgr|INFO|br-int<->unix#1: 3 flow_mods 10 s ago (3 deletes) 2026-02-26T18:34:32.350Z|00091|bridge|INFO|bridge br-int: added interface ovn-2cbbf5-0 on port 2 2026-02-26T18:34:48.090Z|00092|connmgr|INFO|br-int<->unix#1: 3 flow_mods 15 s ago (3 adds) 2026-02-26T18:37:30.568Z|00093|connmgr|INFO|br-int<->unix#44: 21 flow_mods 10 s ago (20 adds, 1 deletes)