2026-03-09T10:06:53.782Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-03-09T10:06:53.866Z|00002|ovs_numa|INFO|Discovered 2 CPU cores on NUMA node 0 2026-03-09T10:06:53.866Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 2 CPU cores 2026-03-09T10:06:53.866Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-03-09T10:06:53.866Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-03-09T10:06:53.869Z|00006|dpdk|INFO|DPDK Disabled - Use other_config:dpdk-init to enable 2026-03-09T10:06:53.877Z|00007|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.5-115.el9s 2026-03-09T10:16:31.656Z|00008|memory|INFO|255820 kB peak resident set size after 577.9 seconds 2026-03-09T10:16:31.656Z|00009|memory|INFO|idl-cells-Open_vSwitch:17 2026-03-09T10:16:31.658Z|00010|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-03-09T10:16:31.658Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-03-09T10:16:31.658Z|00012|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-03-09T10:16:31.659Z|00013|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-03-09T10:16:31.659Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-03-09T10:16:31.659Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-03-09T10:16:31.659Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-03-09T10:16:31.660Z|00017|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-03-09T10:16:31.660Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-03-09T10:16:31.660Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-03-09T10:16:31.660Z|00020|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-03-09T10:16:31.660Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-03-09T10:16:31.661Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-03-09T10:16:31.661Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-03-09T10:16:31.661Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-03-09T10:16:31.661Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-03-09T10:16:31.661Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-03-09T10:16:31.661Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-03-09T10:16:31.661Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-03-09T10:16:31.661Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-03-09T10:16:31.661Z|00030|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-03-09T10:16:31.661Z|00031|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-03-09T10:16:31.661Z|00032|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-03-09T10:16:31.661Z|00033|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 2, setting n-revalidator-threads to 1 2026-03-09T10:16:31.661Z|00034|ofproto_dpif_upcall|INFO|Starting 3 threads 2026-03-09T10:16:31.724Z|00035|netdev|WARN|failed to set MTU for network device br-ex: No such device 2026-03-09T10:16:31.725Z|00036|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2026-03-09T10:16:31.725Z|00037|bridge|INFO|bridge br-ex: using datapath ID 0000525400044683 2026-03-09T10:16:31.725Z|00038|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-03-09T10:16:31.728Z|00039|bridge|INFO|bridge br-ex: added interface enp1s0 on port 1 2026-03-09T10:16:31.742Z|00040|netdev|WARN|failed to set MTU for network device vlan22: No such device 2026-03-09T10:16:31.742Z|00041|bridge|INFO|bridge br-ex: added interface vlan22 on port 2 2026-03-09T10:16:31.768Z|00042|netdev|WARN|failed to set MTU for network device vlan20: No such device 2026-03-09T10:16:31.769Z|00043|bridge|INFO|bridge br-ex: added interface vlan20 on port 3 2026-03-09T10:16:31.788Z|00044|netdev|WARN|failed to set MTU for network device vlan21: No such device 2026-03-09T10:16:31.789Z|00045|bridge|INFO|bridge br-ex: added interface vlan21 on port 4 2026-03-09T10:19:19.152Z|00046|bridge|INFO|bridge br-ex: deleted interface br-ex on port 65534 2026-03-09T10:19:19.309Z|00047|bridge|INFO|bridge br-ex: deleted interface enp1s0 on port 1 2026-03-09T10:19:19.310Z|00048|bridge|INFO|bridge br-ex: deleted interface vlan22 on port 2 2026-03-09T10:19:19.310Z|00049|bridge|INFO|bridge br-ex: deleted interface vlan21 on port 4 2026-03-09T10:19:19.310Z|00050|bridge|INFO|bridge br-ex: deleted interface vlan20 on port 3 2026-03-09T10:19:46.851Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-03-09T10:19:46.966Z|00002|ovs_numa|INFO|Discovered 2 CPU cores on NUMA node 0 2026-03-09T10:19:46.966Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 2 CPU cores 2026-03-09T10:19:46.966Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-03-09T10:19:46.966Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-03-09T10:19:46.969Z|00006|dpdk|INFO|DPDK Disabled - Use other_config:dpdk-init to enable 2026-03-09T10:19:46.982Z|00007|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-03-09T10:19:46.982Z|00008|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-03-09T10:19:46.982Z|00009|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-03-09T10:19:46.982Z|00010|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-03-09T10:19:46.983Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-03-09T10:19:46.983Z|00012|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-03-09T10:19:46.983Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-03-09T10:19:46.983Z|00014|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-03-09T10:19:46.983Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-03-09T10:19:46.983Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-03-09T10:19:46.983Z|00017|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-03-09T10:19:46.983Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-03-09T10:19:46.986Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-03-09T10:19:46.986Z|00020|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-03-09T10:19:46.986Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-03-09T10:19:46.986Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-03-09T10:19:46.986Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-03-09T10:19:46.986Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-03-09T10:19:46.986Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-03-09T10:19:46.986Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-03-09T10:19:46.986Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-03-09T10:19:46.987Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-03-09T10:19:46.987Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-03-09T10:19:46.987Z|00030|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 2, setting n-revalidator-threads to 1 2026-03-09T10:19:46.987Z|00031|ofproto_dpif_upcall|INFO|Starting 3 threads 2026-03-09T10:19:47.008Z|00032|bridge|INFO|bridge br-ex: added interface enp1s0 on port 1 2026-03-09T10:19:47.016Z|00033|netdev|WARN|failed to set MTU for network device vlan22: No such device 2026-03-09T10:19:47.017Z|00034|bridge|INFO|bridge br-ex: added interface vlan22 on port 2 2026-03-09T10:19:47.023Z|00035|netdev|WARN|failed to set MTU for network device vlan20: No such device 2026-03-09T10:19:47.024Z|00036|bridge|INFO|bridge br-ex: added interface vlan20 on port 3 2026-03-09T10:19:47.037Z|00037|netdev|WARN|failed to set MTU for network device vlan21: No such device 2026-03-09T10:19:47.038Z|00038|bridge|INFO|bridge br-ex: added interface vlan21 on port 4 2026-03-09T10:19:47.038Z|00039|bridge|INFO|bridge br-ex: using datapath ID 0000525400044683 2026-03-09T10:19:47.038Z|00040|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-03-09T10:19:47.044Z|00041|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.5-115.el9s 2026-03-09T10:19:47.378Z|00042|bridge|INFO|bridge br-ex: deleted interface vlan21 on port 4 2026-03-09T10:19:47.415Z|00043|bridge|INFO|bridge br-ex: deleted interface enp1s0 on port 1 2026-03-09T10:19:47.415Z|00044|bridge|INFO|bridge br-ex: deleted interface vlan22 on port 2 2026-03-09T10:19:47.415Z|00045|bridge|INFO|bridge br-ex: deleted interface vlan20 on port 3 2026-03-09T10:19:47.593Z|00046|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-03-09T10:19:47.593Z|00047|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-03-09T10:19:47.593Z|00048|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-03-09T10:19:47.593Z|00049|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-03-09T10:19:47.593Z|00050|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-03-09T10:19:47.593Z|00051|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-03-09T10:19:47.593Z|00052|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-03-09T10:19:47.593Z|00053|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-03-09T10:19:47.593Z|00054|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-03-09T10:19:47.593Z|00055|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-03-09T10:19:47.593Z|00056|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-03-09T10:19:47.593Z|00057|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-03-09T10:19:47.594Z|00058|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-03-09T10:19:47.594Z|00059|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-03-09T10:19:47.594Z|00060|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-03-09T10:19:47.594Z|00061|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-03-09T10:19:47.594Z|00062|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-03-09T10:19:47.594Z|00063|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-03-09T10:19:47.594Z|00064|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-03-09T10:19:47.594Z|00065|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-03-09T10:19:47.594Z|00066|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-03-09T10:19:47.594Z|00067|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-03-09T10:19:47.594Z|00068|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-03-09T10:19:47.594Z|00069|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 2, setting n-revalidator-threads to 1 2026-03-09T10:19:47.594Z|00070|ofproto_dpif_upcall|INFO|Starting 3 threads 2026-03-09T10:19:47.632Z|00071|netdev|WARN|failed to set MTU for network device br-ex: No such device 2026-03-09T10:19:47.633Z|00072|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2026-03-09T10:19:47.633Z|00073|bridge|INFO|bridge br-ex: using datapath ID 0000525400044683 2026-03-09T10:19:47.633Z|00074|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-03-09T10:19:47.668Z|00075|netdev|WARN|failed to set MTU for network device vlan20: No such device 2026-03-09T10:19:47.669Z|00076|bridge|INFO|bridge br-ex: added interface vlan20 on port 1 2026-03-09T10:19:47.703Z|00077|netdev|WARN|failed to set MTU for network device vlan21: No such device 2026-03-09T10:19:47.704Z|00078|bridge|INFO|bridge br-ex: added interface vlan21 on port 2 2026-03-09T10:19:47.707Z|00079|bridge|INFO|bridge br-ex: added interface enp1s0 on port 3 2026-03-09T10:19:47.732Z|00080|netdev|WARN|failed to set MTU for network device vlan22: No such device 2026-03-09T10:19:47.733Z|00081|bridge|INFO|bridge br-ex: added interface vlan22 on port 4 2026-03-09T10:19:57.046Z|00082|memory|INFO|265096 kB peak resident set size after 10.2 seconds 2026-03-09T10:19:57.047Z|00083|memory|INFO|handlers:2 idl-cells-Open_vSwitch:324 ports:5 revalidators:1 rules:5 udpif keys:17 2026-03-09T10:22:20.900Z|00084|bridge|INFO|bridge br-int: added interface br-int on port 65534 2026-03-09T10:22:20.900Z|00085|bridge|INFO|bridge br-int: using datapath ID 00005e01b5e61080 2026-03-09T10:22:20.901Z|00086|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2026-03-09T10:22:20.951Z|00087|bridge|INFO|bridge br-int: added interface ovn-e43e49-0 on port 1 2026-03-09T10:22:38.915Z|00088|connmgr|INFO|br-int<->unix#1: 21 flow_mods 10 s ago (20 adds, 1 deletes) 2026-03-09T10:42:37.120Z|00089|connmgr|INFO|br-int<->unix#41: 21 flow_mods 10 s ago (20 adds, 1 deletes)