2026-02-26T16:27:01.408Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-02-26T16:27:01.478Z|00002|ovs_numa|INFO|Discovered 6 CPU cores on NUMA node 0 2026-02-26T16:27:01.478Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 6 CPU cores 2026-02-26T16:27:01.478Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-02-26T16:27:01.478Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-02-26T16:27:01.481Z|00006|dpdk|INFO|DPDK Disabled - Use other_config:dpdk-init to enable 2026-02-26T16:27:01.490Z|00007|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.5-115.el9s 2026-02-26T16:33:14.036Z|00008|memory|INFO|255776 kB peak resident set size after 370.8 seconds 2026-02-26T16:33:14.036Z|00009|memory|INFO|idl-cells-Open_vSwitch:17 2026-02-26T16:33:14.037Z|00010|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-02-26T16:33:14.038Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-02-26T16:33:14.038Z|00012|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-02-26T16:33:14.038Z|00013|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-02-26T16:33:14.038Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-02-26T16:33:14.038Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-02-26T16:33:14.038Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-02-26T16:33:14.038Z|00017|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-02-26T16:33:14.038Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-02-26T16:33:14.038Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-02-26T16:33:14.038Z|00020|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-02-26T16:33:14.038Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-02-26T16:33:14.038Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-02-26T16:33:14.038Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-02-26T16:33:14.038Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-02-26T16:33:14.038Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-02-26T16:33:14.038Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-02-26T16:33:14.038Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-02-26T16:33:14.038Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-02-26T16:33:14.038Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-02-26T16:33:14.038Z|00030|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-02-26T16:33:14.038Z|00031|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-02-26T16:33:14.038Z|00032|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-02-26T16:33:14.038Z|00033|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 6, setting n-revalidator-threads to 2 2026-02-26T16:33:14.038Z|00034|ofproto_dpif_upcall|INFO|Starting 8 threads 2026-02-26T16:33:14.080Z|00035|netdev|WARN|failed to set MTU for network device br-ex: No such device 2026-02-26T16:33:14.085Z|00036|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2026-02-26T16:33:14.085Z|00037|bridge|INFO|bridge br-ex: using datapath ID 0000525400d3043c 2026-02-26T16:33:14.085Z|00038|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-02-26T16:33:14.095Z|00039|netdev|WARN|failed to set MTU for network device vlan22: No such device 2026-02-26T16:33:14.097Z|00040|bridge|INFO|bridge br-ex: added interface vlan22 on port 1 2026-02-26T16:33:14.103Z|00041|netdev|WARN|failed to set MTU for network device vlan21: No such device 2026-02-26T16:33:14.104Z|00042|bridge|INFO|bridge br-ex: added interface vlan21 on port 2 2026-02-26T16:33:14.108Z|00043|netdev|WARN|failed to set MTU for network device vlan20: No such device 2026-02-26T16:33:14.109Z|00044|bridge|INFO|bridge br-ex: added interface vlan20 on port 3 2026-02-26T16:33:14.111Z|00045|bridge|INFO|bridge br-ex: added interface enp1s0 on port 4 2026-02-26T16:33:14.337Z|00046|bridge|INFO|bridge br-ex: deleted interface enp1s0 on port 4 2026-02-26T16:33:14.355Z|00047|bridge|INFO|bridge br-ex: added interface enp1s0 on port 5 2026-02-26T16:38:33.398Z|00048|bridge|INFO|bridge br-int: added interface br-int on port 65534 2026-02-26T16:38:33.398Z|00049|bridge|INFO|bridge br-int: using datapath ID 0000eaeda8f1a2e7 2026-02-26T16:38:33.399Z|00050|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2026-02-26T16:38:33.466Z|00051|bridge|INFO|bridge br-int: added interface ovn-fdf271-0 on port 1 2026-02-26T16:38:51.429Z|00052|connmgr|INFO|br-int<->unix#1: 21 flow_mods 10 s ago (20 adds, 1 deletes)